Loading...
HomeMy WebLinkAbout1991-3401 Uniform Plumbing Code 044- ORDINANCE NO. 3 4- 01 AN ORDINANCE relating to building regulations; adopting by reference the Uniform Plumbing Code, 1991 Edition, of the International Association of Plumbing and Mechanical Officials; amending Sections 11 44 010, 11 44 040, 11 44 041, 11 44 042 and Subsection 11 44 050 B; all of the City of Yakima Municipal Code WHEREAS, R C W 35 21 180 authorized cities and towns within the State of Washington to pass ordinances adopting by reference compilations and codes relating to the construction of buildings, and WHEREAS, the City Council of the City of Yakima has heretofore examined and understands the scope and purpose of the Uniform Plumbing Code, 1991 Edition, of the International Association of Plumbing and Mechanical Officials, and deems it in the best interests of the City that such Uniform • Plumbing, Code be adopted as the law of the City of Yakima, and WHEREAS, one or more copies of such Uniform Plumbing Code have heretofore been filed in the office of the Code Administration Manager of the City of Yakima for use and examination by the public, as required by law, now, therefore, BE IT ORDAINED BY THE CITY OF YAKIMA $Prtion 1 Section 11 44 010 of the City of Yakima Municipal Code is hereby amended to read as follows "11 44 010 Adoption of Uniform Plumbing Code The Uniform Plumbing Code, 1985 Edition, of the International Association of Plumbing and Officials, excluding Chapter 12, together with and including ® Mechanical IAPMO installation standards and appendices thereto, consisting of Appendix A, 'Rules for Sizing the Water Systems', Appendix B, PLANVI D 1 - B/7/91 'Combination Waste and Vent Systems', Appendix C, 'Minimum Plumbing Facilities', Appendix D, 'Rainwater Systems', Appendix E, 'Mobile Home Parks Plumbing Standards', Appendix G, 'Swimming Pools', Appendix H, 'Sizing Commercial Kitchen Grease Interceptors', and Appendix I, 'Private Sewage Disposal Systems', of which one or more copies each have been filed and now are on file in the office of the Code Administration Manager of the City of Yakima, is hereby adopted and incorporated as fully as if set out in full herein, as the plumbing code of the City of Yakima, except as hereinafter amended, and the provisions and regulations thereof are hereby adopted as the provisions and regulations of the City of Yakima; and the several sections or numbers therein shall constitute, and may be referred to as, the numbers of this chapter " $or'tion 2 Section 11 44 040 of the City of Yakima Municipal Code is hereby amended to read as follows "11 44 040 Amendment to Part 1 - Administration Part 1, Administration, of the Uniform Plumbing Code, as applied to the City of Yakima, is hereby amended to read as follows ' 10 1 Title This ordinance shall be known as the 'Uniform Plumbing Code' and will be referred to as 'this Code' herein 10 2 Purpose This Code is an ordinance providing minimum requirements and standards for the protection of the public health, safety and welfare Enforcement and adoption of this Code shall not be construed for the particular benefit of any individual person or group of persons, other than the general public In the event of a conflict between the intent of this sub - section and any other section herein, this sub - section shall govern insofar as applicable 10 3 Scope (a) The provisions of this Code shall apply to the erection, installation, alteration, repair, relocation, replacement, addition to, use or maintenance of plumbing systems within this jurisdiction (b) Additions, alterations, repairs and replacement of plumbing systems shall comply with the provisions for new systems except as otherwise provided in Section 10 4 of this part (c) The provisions in the appendix are intended to supplement the installation requirements of this Code The provisions in the Installation Standards shall not be considered part of the Uniform Plumbing Code unless formally adopted as such 10 4 Application to Existing Plumbing System (a) Additions, Alterations or Repairs Additions, alterations or repairs may be made to any plumbing system without requiring the existing plumbing system to comply with all the requirements of this Code, provided the addition, alteration or repair conforms to that required for PLANV! D 2 - 8/7'91 :r a new plumbing system Additions, alterations or repairs shall not cause Illr existing system to become unsafe, insanitary or overloaded (b) Existing Installation Plumbing systems lawfully in existence at the time of the adoption of this Code may have their use, maintenance or repair continued if the use, maintenance or repair is in accordance with the original design and location and no hazard to life, health or property has been created by such plumbing system (c) Changes in Building Occupancy Plumbing systems which are a part of any building or structure undergoing a change in use or occupancy, as defined in the Building Code, shall comply to all requirements of this Code which may be applicable to the new use or occupancy (d) Maintenance All plumbing systems, materials and appurtenances, both existing and new, and all parts thereof shall be maintained in proper operating condition All devices or safeguards required by this Code shall be maintained in conformance with the Code edition under which installed The owner or his designated agent shall be responsible for maintenance of plumbing systems To determine compliance with this subsection, the Administrative Authority may cause any plumbing system to be reinspected (e) Moved Buildings Plumbing systems which are part of buildings or structures moved into this jurisdiction shall comply with the • provisions of this Code for new installations 10 5 Authority to Abate (a) Any portion of a plumbing system found by the Administrative Authority to be insanitary, as defined herein, is hereby declared to be a nuisance (b) Where a nuisance exists or a plumbing system is maintained in violation of this Code or any notice issued pursuant to this section, the Administrative Authority shall require the nuisance or violation to be abated and, where necessary, shall seek such abatement in the manner provided by law 20 1 Administrative Authority Whenever the term 'Administrative Authority' is used in this Code, it shall mean the Code Administration Manager or his authorized representative 20 2 Duties and Powers of Administrative Authority (a) The Administrative Authority may appoint such assistants, deputies, inspectors, or other employees as are necessary to carry out the functions of the department and this Code (b) Right of Entry Whenever it is necessary to make an inspection to enforce the provisions of this Code, or whenever the Administrative • Authority or his authorized representative has reasonable cause to believe that there exists in any building or upon any premises, any PLANVJ D 3 -61/7/91 1 condition or violation of this Code which make the building or premises unsafe, insanitary, dangerous or hazardous, the Administrative Authority or his authorized representative may enter the building or premises at all reasonable times to inspect or to perform the duties imposed upon the Administrative •Authority by this Code, provided that if such building or premises is occupied, he shall present his credentials to the occupant and request entry If such building or premises is unoccupied, he shall first make a reasonable effort to locate the owner or the other person having charge or control of the building or premises and request entry If entry is refused, the Administrative Authority or his authorized representative has recourse to every remedy provided by law to secure entry When the Administrative Authority or his authorized representative shall have first obtained a proper inspection warrant or other remedy provided by law to secure entry, no owner, occupant, or person having charge, care, or control of any building or premises shall fail or neglect, after proper request is made as herein provided, to promptly permit entry herein by the Administrative Authority or his authorized representative for the purpose of inspection and examination pursuant to this Code (c) Stop Orders Whenever any work is being done contrary to the provisions of this Code, the Administrative Authority may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done, and any such persons shall forthwith stop work until authorized by the Administrative Authority to proceed with the work (d) Authority to Disconnect Utilities in Emergencies The Administrative Authority and his authorized representative shall have the authority to disconnect a plumbing system to a building, structure or equipment regulated by this Code in case of emergency where necessary to eliminate an immediate hazard to life or property (e) Authority to Condemn Whenever the Administrative Authority ascertains that any plumbing system or portion thereof, regulated by this Code, has become hazardous to life, health, property, or has become insanitary, he shall order in writing that such plumbing either be removed or placed in a safe or sanitary condition, as appropriate The order shall fix a reasonable time limit for compliance No person shall use or maintain defective plumbing after receiving such notice When such plumbing system is to be disconnected, written notice shall be given In cases of immediate danger to life or property, such disconnection may be made immediately without such notice (f) Liability The Administrative Authority or his authorized representative, charged with the enforcement of this Code, acting in good faith and without malice in the discharge of duties, shall not thereby render himself personally liable for any damage that may accrue to the persons or property as a result of any act or by reason of any act or omission in the discharge of his duties A suit brought against the • Administrative Authority or employee because of such act or omission PLANVI D 4 8/7i91 -v performed by h in the enforcement of any provision of this Code shall be defended by legal counsel provided by this jurisdiction until final termination of such proceedings 20 3 Violation and penalties (a) Any person, firm or corporation violating any provision of this Code shall be deemed guilty of a misdemeanor and, upon conviction thereof, shall be punishable by a fine not to exceed $250 00, or by imprisonment in the jail facility for the City of Yakima for not to exceed 90 days, or by both such fine and imprisonment Each separate day or any portion thereof, during which any violation of this Code occurs or continues, shall be deemed to constitute a separate offense and, upon conviction thereof, shall be punishable as herein provided. The issuance or granting of a permit or approval of plans and specifications shall not be deemed or construed to be a permit for, or an approval of, any - violation of any of the provisions of this Code No permit presuming to give authority to violate or cancel the provisions of this Code shall be valid, except insofar as the work or use which it authorized is lawful (b) The issuance or granting of a permit or approval of plans shall not prevent the Administrative Authority from thereafter requiring the correction of errors in said plans and specifications or from preventing construction operations being carried on thereunder when in violation of this Code or any other ordinance or from revoking any Certificate of Approval when issued in error • (c) Every permit issued by the Administrative Authority under the provisions of this Code shall expire by limitation and become null and void if the work authorized by such permit is not commenced within 180 days from the date of issuance of such permit, or if the work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days Before such work may be recommenced, a new permit shall first be obtained to do so Section 5 Subsection 11 44 050 B of the City of Yakima Municipal Code is hereby amended to read as follows "11 44 050 Oualification of Plumbers B License Procurement and Fees (1) All contractors licenses required by this chapter shall be obtained from the Washington Department of Labor and Industries, Professional Licensing Division, and shall be maintained in accordance with Title 18 of the Revised Code of Washington • PLANVI D 5 - 8/7191 tl (2) All Journeyman Plumbers Certificate of Competency required by this chapter shall be obtained from the Washington Department of Labor _111, and Industries, Building and Construction Safety Inspection Division, and shall be maintained in accordance with Title 18 of the Revised Code of Washington (3) All Journeyman Side Sewer Installers Licenses required by this chapter shall be obtained from the Code Administration Manager or his designee upon presentation of a Certificate of Qualification issued and approved by the Division of Code Administration License fees shall be paid to the City of Yakima at time of issuance in accordance with the following schedule Original Benewal Journeyman Side Sewer Installers License $10 00 $10 00 Licenses expire on December 31st of each year " $action 3. Section 11 44 041 of the City of Yakima Municipal Code is hereby amended to read as follows "11 44 041 Amendment to Subsection (c) of Section 102 of the Uniform plumbing Code Subsection (c) of Section 102 of the Uniform Plumbing Code is hereby amended to read as follows '(c) Administrative Authority The Administrative Authority is the Code Administration Manager or the Director of the Department of Community and Economic Development or their respective designees ' " Section 4 Section 11 44 042 of the City of Yakima Municipal Code is hereby amended to read as follows "11 44 042 Amendment to Subsection (e) of. Section 120 of the Uniform Plumbing Code Subsection (e) of Section 120 of the Uniform Plumbing Code is hereby amended to read as follows 'Shall -- The word "shall" is defined to have the following meaning (1) With respect to the functions and powers of the Director of Community and Economic Development, Code Administration Manager, any agents and employees of the City of Yakima and any board authorized hereunder, a direction and authorization to act in the exercise of sound discretion and in good faith • PLANVI D 6 - 6/7/91 w (2) With respect to the obligations upon owners and occupants of premises and their agents, a mandatory requirement to act in compliance with this Code at the risk of civil and criminal liability upon failure so to act '" $Potion 5 Section 11 44 120 of the City of Yakima Municipal Code is hereby enacted to read as follows "11 44 120 Amendment to Section 1004 of the Uniform Plumbing Code Section 1004 of the Uniform Plumbing Code is hereby amended to read as follows 'Section 1004 - Materials (a) Water pipe and fittings shall be of brass, copper, cast iron, galvanized steel, or other approved materials Asbestos - cement, CPVC, PB, PE, or PVC water pipe manufactured to recognized standards may be used for cold water distribution systems outside a building. CPVC and PB water pipe and tubing may be used for hot and cold water distribution systems within a building All materials used in the water supply system, except valves and similar devices shall be of a like material, except where otherwise approved by the Administrative Authority (b) Cast iron fittings up to and including two (2) inches (50 8 mm) in size, when used in connection with potable water piping shall be galvanized (c) All malleable iron water fittings shall be galvanized (d) Piping and tubing which has previously been used for any purpose other than for potable water systems shall not be used (e) Approved plastic materials may be used in water service piping, provided that where metal water service piping is used for electrical grounding purposes, replacement piping therefore shall be of like materials Exception Where a grounding system, acceptable to the Administrative Authority is installed, inspected, and approved, metallic pipe may be replaced with non - metallic pipe (f) Solder shall conform to the requirements of Section '802(d) (g) Water pipe and fittings with a lead content which exceeds eight (8) percent shall be prohibited in piping systems used to convey potable water ' " PLANVI D 7 - 8/7/91 SPrt.inn 6 This ordinance shall be in full force and effect thirty 411 days after its passage, approval and publication as provided by law and by the City Charter PASSED BY THE CITY COUNCIL, signed and approved this day of , 1991 C)a-t MAYOR ATTEST CITY CLERK • PLANV! D 8 - 817i91