HomeMy WebLinkAbout1991-3401 Uniform Plumbing Code 044- ORDINANCE NO. 3 4- 01
AN ORDINANCE relating to building regulations; adopting by reference the
Uniform Plumbing Code, 1991 Edition, of the International
Association of Plumbing and Mechanical Officials; amending
Sections 11 44 010, 11 44 040, 11 44 041, 11 44 042 and
Subsection 11 44 050 B; all of the City of Yakima Municipal
Code
WHEREAS, R C W 35 21 180 authorized cities and towns within the State
of Washington to pass ordinances adopting by reference compilations and codes
relating to the construction of buildings, and
WHEREAS, the City Council of the City of Yakima has heretofore examined
and understands the scope and purpose of the Uniform Plumbing Code, 1991
Edition, of the International Association of Plumbing and Mechanical
Officials, and deems it in the best interests of the City that such Uniform
• Plumbing, Code be adopted as the law of the City of Yakima, and
WHEREAS, one or more copies of such Uniform Plumbing Code have
heretofore been filed in the office of the Code Administration Manager of the
City of Yakima for use and examination by the public, as required by law, now,
therefore,
BE IT ORDAINED BY THE CITY OF YAKIMA
$Prtion 1 Section 11 44 010 of the City of Yakima Municipal Code is
hereby amended to read as follows
"11 44 010 Adoption of Uniform Plumbing Code The Uniform Plumbing
Code, 1985 Edition, of the International Association of Plumbing and
Officials, excluding Chapter 12, together with and including
® Mechanical IAPMO installation standards and appendices thereto, consisting of
Appendix A, 'Rules for Sizing the Water Systems', Appendix B,
PLANVI D
1 - B/7/91
'Combination Waste and Vent Systems', Appendix C, 'Minimum Plumbing
Facilities', Appendix D, 'Rainwater Systems', Appendix E, 'Mobile Home
Parks Plumbing Standards', Appendix G, 'Swimming Pools', Appendix H,
'Sizing Commercial Kitchen Grease Interceptors', and Appendix I, 'Private
Sewage Disposal Systems', of which one or more copies each have been
filed and now are on file in the office of the Code Administration
Manager of the City of Yakima, is hereby adopted and incorporated as
fully as if set out in full herein, as the plumbing code of the City of
Yakima, except as hereinafter amended, and the provisions and regulations
thereof are hereby adopted as the provisions and regulations of the City
of Yakima; and the several sections or numbers therein shall constitute,
and may be referred to as, the numbers of this chapter "
$or'tion 2 Section 11 44 040 of the City of Yakima Municipal Code
is hereby amended to read as follows
"11 44 040 Amendment to Part 1 - Administration Part 1,
Administration, of the Uniform Plumbing Code, as applied to the City of
Yakima, is hereby amended to read as follows
' 10 1 Title This ordinance shall be known as the 'Uniform
Plumbing Code' and will be referred to as 'this Code' herein
10 2 Purpose This Code is an ordinance providing minimum
requirements and standards for the protection of the public health,
safety and welfare Enforcement and adoption of this Code shall not be
construed for the particular benefit of any individual person or group of
persons, other than the general public In the event of a conflict
between the intent of this sub - section and any other section herein, this
sub - section shall govern insofar as applicable
10 3 Scope
(a) The provisions of this Code shall apply to the erection,
installation, alteration, repair, relocation, replacement, addition to,
use or maintenance of plumbing systems within this jurisdiction
(b) Additions, alterations, repairs and replacement of plumbing
systems shall comply with the provisions for new systems except as
otherwise provided in Section 10 4 of this part
(c) The provisions in the appendix are intended to supplement the
installation requirements of this Code
The provisions in the Installation Standards shall not be considered
part of the Uniform Plumbing Code unless formally adopted as such
10 4 Application to Existing Plumbing System
(a) Additions, Alterations or Repairs Additions, alterations or
repairs may be made to any plumbing system without requiring the existing
plumbing system to comply with all the requirements of this Code,
provided the addition, alteration or repair conforms to that required for
PLANV! D
2 - 8/7'91
:r
a new plumbing system Additions, alterations or repairs shall not cause
Illr existing system to become unsafe, insanitary or overloaded
(b) Existing Installation Plumbing systems lawfully in existence
at the time of the adoption of this Code may have their use, maintenance
or repair continued if the use, maintenance or repair is in accordance
with the original design and location and no hazard to life, health or
property has been created by such plumbing system
(c) Changes in Building Occupancy Plumbing systems which are a
part of any building or structure undergoing a change in use or
occupancy, as defined in the Building Code, shall comply to all
requirements of this Code which may be applicable to the new use or
occupancy
(d) Maintenance All plumbing systems, materials and
appurtenances, both existing and new, and all parts thereof shall be
maintained in proper operating condition All devices or safeguards
required by this Code shall be maintained in conformance with the Code
edition under which installed The owner or his designated agent shall
be responsible for maintenance of plumbing systems To determine
compliance with this subsection, the Administrative Authority may cause
any plumbing system to be reinspected
(e) Moved Buildings Plumbing systems which are part of buildings
or structures moved into this jurisdiction shall comply with the
• provisions of this Code for new installations
10 5 Authority to Abate
(a) Any portion of a plumbing system found by the Administrative
Authority to be insanitary, as defined herein, is hereby declared to be a
nuisance
(b) Where a nuisance exists or a plumbing system is maintained in
violation of this Code or any notice issued pursuant to this section, the
Administrative Authority shall require the nuisance or violation to be
abated and, where necessary, shall seek such abatement in the manner
provided by law
20 1 Administrative Authority Whenever the term 'Administrative
Authority' is used in this Code, it shall mean the Code Administration
Manager or his authorized representative
20 2 Duties and Powers of Administrative Authority
(a) The Administrative Authority may appoint such assistants,
deputies, inspectors, or other employees as are necessary to carry out
the functions of the department and this Code
(b) Right of Entry Whenever it is necessary to make an inspection
to enforce the provisions of this Code, or whenever the Administrative
• Authority or his authorized representative has reasonable cause to
believe that there exists in any building or upon any premises, any
PLANVJ D
3 -61/7/91
1
condition or violation of this Code which make the building or premises
unsafe, insanitary, dangerous or hazardous, the Administrative Authority
or his authorized representative may enter the building or premises at
all reasonable times to inspect or to perform the duties imposed upon the
Administrative •Authority by this Code, provided that if such building or
premises is occupied, he shall present his credentials to the occupant
and request entry If such building or premises is unoccupied, he shall
first make a reasonable effort to locate the owner or the other person
having charge or control of the building or premises and request entry
If entry is refused, the Administrative Authority or his authorized
representative has recourse to every remedy provided by law to secure
entry
When the Administrative Authority or his authorized
representative shall have first obtained a proper inspection warrant or
other remedy provided by law to secure entry, no owner, occupant, or
person having charge, care, or control of any building or premises shall
fail or neglect, after proper request is made as herein provided, to
promptly permit entry herein by the Administrative Authority or his
authorized representative for the purpose of inspection and examination
pursuant to this Code
(c) Stop Orders Whenever any work is being done contrary to the
provisions of this Code, the Administrative Authority may order the work
stopped by notice in writing served on any persons engaged in the doing
or causing such work to be done, and any such persons shall forthwith
stop work until authorized by the Administrative Authority to proceed
with the work
(d) Authority to Disconnect Utilities in Emergencies The
Administrative Authority and his authorized representative shall have the
authority to disconnect a plumbing system to a building, structure or
equipment regulated by this Code in case of emergency where necessary to
eliminate an immediate hazard to life or property
(e) Authority to Condemn Whenever the Administrative Authority
ascertains that any plumbing system or portion thereof, regulated by this
Code, has become hazardous to life, health, property, or has become
insanitary, he shall order in writing that such plumbing either be
removed or placed in a safe or sanitary condition, as appropriate The
order shall fix a reasonable time limit for compliance No person shall
use or maintain defective plumbing after receiving such notice
When such plumbing system is to be disconnected, written notice
shall be given In cases of immediate danger to life or property, such
disconnection may be made immediately without such notice
(f) Liability The Administrative Authority or his authorized
representative, charged with the enforcement of this Code, acting in good
faith and without malice in the discharge of duties, shall not thereby
render himself personally liable for any damage that may accrue to the
persons or property as a result of any act or by reason of any act or
omission in the discharge of his duties A suit brought against the
•
Administrative Authority or employee because of such act or omission
PLANVI D
4 8/7i91
-v
performed by h in the enforcement of any provision of this Code shall
be defended by legal counsel provided by this jurisdiction until final
termination of such proceedings
20 3 Violation and penalties
(a) Any person, firm or corporation violating any provision of this
Code shall be deemed guilty of a misdemeanor and, upon conviction
thereof, shall be punishable by a fine not to exceed $250 00, or by
imprisonment in the jail facility for the City of Yakima for not to
exceed 90 days, or by both such fine and imprisonment Each separate day
or any portion thereof, during which any violation of this Code occurs or
continues, shall be deemed to constitute a separate offense and, upon
conviction thereof, shall be punishable as herein provided. The issuance
or granting of a permit or approval of plans and specifications shall not
be deemed or construed to be a permit for, or an approval of, any -
violation of any of the provisions of this Code No permit presuming to
give authority to violate or cancel the provisions of this Code shall be
valid, except insofar as the work or use which it authorized is lawful
(b) The issuance or granting of a permit or approval of plans shall
not prevent the Administrative Authority from thereafter requiring the
correction of errors in said plans and specifications or from preventing
construction operations being carried on thereunder when in violation of
this Code or any other ordinance or from revoking any Certificate of
Approval when issued in error
• (c) Every permit issued by the Administrative Authority under the
provisions of this Code shall expire by limitation and become null and
void if the work authorized by such permit is not commenced within 180
days from the date of issuance of such permit, or if the work authorized
by such permit is suspended or abandoned at any time after the work is
commenced for a period of 180 days Before such work may be recommenced,
a new permit shall first be obtained to do so
Section 5 Subsection 11 44 050 B of the City of Yakima Municipal
Code is hereby amended to read as follows
"11 44 050 Oualification of Plumbers
B License Procurement and Fees
(1) All contractors licenses required by this chapter shall be
obtained from the Washington Department of Labor and Industries,
Professional Licensing Division, and shall be maintained in accordance
with Title 18 of the Revised Code of Washington
•
PLANVI D
5 - 8/7191
tl
(2) All Journeyman Plumbers Certificate of Competency required by
this chapter shall be obtained from the Washington Department of Labor _111,
and Industries, Building and Construction Safety Inspection Division, and
shall be maintained in accordance with Title 18 of the Revised Code of
Washington
(3) All Journeyman Side Sewer Installers Licenses required by this
chapter shall be obtained from the Code Administration Manager or his
designee upon presentation of a Certificate of Qualification issued and
approved by the Division of Code Administration License fees shall be
paid to the City of Yakima at time of issuance in accordance with the
following schedule
Original Benewal
Journeyman Side Sewer Installers License $10 00 $10 00
Licenses expire on December 31st of each year "
$action 3. Section 11 44 041 of the City of Yakima Municipal Code
is hereby amended to read as follows
"11 44 041 Amendment to Subsection (c) of Section 102 of the Uniform
plumbing Code Subsection (c) of Section 102 of the Uniform Plumbing
Code is hereby amended to read as follows
'(c) Administrative Authority The Administrative Authority is
the Code Administration Manager or the Director of the Department of
Community and Economic Development or their respective designees ' "
Section 4 Section 11 44 042 of the City of Yakima Municipal Code
is hereby amended to read as follows
"11 44 042 Amendment to Subsection (e) of. Section 120 of the
Uniform Plumbing Code Subsection (e) of Section 120 of the Uniform
Plumbing Code is hereby amended to read as follows
'Shall -- The word "shall" is defined to have the following meaning
(1) With respect to the functions and powers of the Director of
Community and Economic Development, Code Administration Manager, any
agents and employees of the City of Yakima and any board authorized
hereunder, a direction and authorization to act in the exercise of sound
discretion and in good faith
•
PLANVI D
6 - 6/7/91
w
(2) With respect to the obligations upon owners and occupants of
premises and their agents, a mandatory requirement to act in compliance
with this Code at the risk of civil and criminal liability upon failure
so to act '"
$Potion 5 Section 11 44 120 of the City of Yakima Municipal Code
is hereby enacted to read as follows
"11 44 120 Amendment to Section 1004 of the Uniform Plumbing Code
Section 1004 of the Uniform Plumbing Code is hereby amended to read as
follows
'Section 1004 - Materials
(a) Water pipe and fittings shall be of brass, copper, cast iron,
galvanized steel, or other approved materials Asbestos - cement, CPVC,
PB, PE, or PVC water pipe manufactured to recognized standards may be
used for cold water distribution systems outside a building. CPVC and PB
water pipe and tubing may be used for hot and cold water distribution
systems within a building All materials used in the water supply
system, except valves and similar devices shall be of a like material,
except where otherwise approved by the Administrative Authority
(b) Cast iron fittings up to and including two (2) inches (50 8 mm)
in size, when used in connection with potable water piping shall be
galvanized
(c) All malleable iron water fittings shall be galvanized
(d) Piping and tubing which has previously been used for any
purpose other than for potable water systems shall not be used
(e) Approved plastic materials may be used in water service piping,
provided that where metal water service piping is used for electrical
grounding purposes, replacement piping therefore shall be of like
materials
Exception Where a grounding system, acceptable to the
Administrative Authority is installed, inspected, and
approved, metallic pipe may be replaced with non - metallic
pipe
(f) Solder shall conform to the requirements of Section '802(d)
(g) Water pipe and fittings with a lead content which exceeds eight
(8) percent shall be prohibited in piping systems used to convey potable
water ' "
PLANVI D
7 - 8/7/91
SPrt.inn 6 This ordinance shall be in full force and effect thirty
411
days after its passage, approval and publication as provided by law and by the
City Charter
PASSED BY THE CITY COUNCIL, signed and approved this day of
, 1991
C)a-t
MAYOR
ATTEST
CITY CLERK
•
PLANV! D
8 - 817i91