HomeMy WebLinkAboutR-2004-168 Whitecotton Final PlatRESOLUTION NO. R-2004-168
A RESOLUTION approving the final plat of Whitecotton, an 11 -lot subdivision located at the
intersection of Rock and Mead Avenues, and authorizing the Mayor to sign the
final plat of Whitecotton, Dale Whitecotton as applicant therein.
WHEREAS, on March 25, 2004 the Hearing Examiner held a public hearing to consider the
application for a subdivision known as Whitecotton, located at the intersection of Rock and Mead Avenues,
submitted by Dale Whitecotton, City Preliminary Plat #1-04; and
WHEREAS, on April 8, 2004, the Hearing Examiner issued his Examiner's Recommendation
approving the proposed plat subject to several conditions; and
WHEREAS, at its public meeting on May 18, 2004, the City Council determined by motion that
the Recommendation of the Hearing Examiner should be affirmed and adopted, together with the findings
of the Hearing Examiner contained therein pursuant to Ch. 58.17 RCW, including but not limited to RCW
sections 58.17.110 and RCW 58.17.195 (the "Examiner's Findings"); and
WHEREAS, the applicant has completed construction or bonded for all public improvements
required as conditions of approval of the preliminary plat, and the City Engineer has inspected, approved
and accepted all such required improvements; and
WHEREAS, as this final plat comes before City Council for review each member declares that he
has had no contact with either the applicant or opponents of the final plat, now, therefore,
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF YAKIMA:
The proposed final plat for Whitecotton, consisting of 1 sheets dated September 3,
2004 , showing a eleven lot subdivision located at the intersection of Rock and Mead Avenues, is
hereby approved pursuant to the Examiner's Findings, which are hereby adopted as the findings of the City
Council and are incorporated by this reference as if set forth fully herein, and the Mayor is hereby
authorized to sign the final plat. The final plat for Whitecotton shall be filed for record by the applicant in
the Yakima County Auditor's Office immediately, or as soon thereafter as possible, and the applicant shall
be responsible for all filing fees.
ADOPTED BY THE CITY COUNCIL this 2nd of Noveanber , 2004.
ATTEST:
Paul George, Mayor
City Clerk
FINAL PLAT OF WHITECOTTON
Submitted by Dale Whitecotton
EXHIBIT LIST
City Council Public Meeting
November 2, 2004
List of Attachments:
Resolution
Staff Report
Hearing Examiner's Recommendation
Vicinity Map
Final Plat
City of Yakima, Washington
Department of Community & Economic Development
Office of Environmental Planning
CITY COUNCIL PUBLIC MEETING
November 2, 2004
Final Long Plat Consideration ) Final Long Plat #1-04
for the Plat of Whitecotton (11 lots) ) Jeff Peters
Submitted by Dale Whitecotton ) Assistant Planner
Location, intersection of Mead Ave. ) 575-6163
and Rock Ave. )
SUMMARY OF RECOMMENDATION.
All requirements conditional to the final approval of this plat have been satisfied. The Division of
Environmental Planning recommends Council acceptance of the final plat of Creekview.
FINDINGS
BACKGROUND.
Creekview is a new 11 -lot subdivision located at the intersection of Mead Ave and Rock Ave. In
open Council session on May 18, 2004, the Hearing Examiner's recommendation, granting
preliminary approval of this long plat, was accepted.
COMPREHENSIVE PLAN.
The Optimal Land Use Element of the Comprehensive Plan indicates that from one to eleven
dwelling units per acre characterizes the R-2 zoning district.
The Plan also provides goals and policies directed towards provision of adequate public utilities to
new developments. This site is now fully serviced by all necessary public utilities with access
provided by both Mead and Rock Avenues.
ZONING.
The R-2 zoning district is characterized by 50 percent maximum lot coverage, access via local
access streets and collectors, one and two story buildings, some clustering of units and large front,
rear and side yard building setbacks.
SUBDIVISION ORDINANCE STANDARDS.
Criteria for subdivisions are included in YMC 14.25.110, which specifies the requirements for
subdivision design. The Whitecotton plat has been found to comply with all applicable standards
and the final plat is in general conformance with the preliminary design.
ENVIRONMENTAL REVIEW.
Plat of Whitecotton
Final Long Plat # 1-04
Dale Whitecotton
Intersection of Mead Ave and Rock Ave
1
A Determination of Nonsignificance was issued for this subdivision. on March 2, 2004. This
determination was issued following a 20 -day comment period. No comments were received and
no appeal was filed. No additional SEPA review is required for this Final Plat.
CONDITIONS, OF APPROVAL.
The approved preliminary plat required the applicant to complete all site improvements listed as
conditions in the Hearing Examiner's Recommendation of April 8, 2004 (see attached).
The conditions that must be met before the final plat can be approved consist of the following:
1. The residential driveway approach form Lot 1 onto Mead Ave. shall be removed and
replaced with matching curb.
2. A sidewalk five (5) feet in width shall be installed along Rock Ave, with either a rolled or
barrier curb at the owner's option.
3. Additional sewer stubs shall be installed to connect either with the sewer line along Rock
Ave. or with the sewer line along the rear (east) property line at the owner's option, one
sewer stub for each structure that shall be extended to the property line of each parcel.
Status: Items 1 — 3 above: All street improvements have been engineered, reviewed
and financially secured by bond in the amount of $9,303.25. The City Engineer has
evidenced his approval by signing the final plat.
4. The property corner where Rock Avenue intersects with Mead Ave shall be rounded to a
radius of twenty (20) feet and the property necessary to accomplish that result shall be
dedicated.
Status: All street improvements have been engineered, reviewed and financially
secured by bond in the amount of $9, 303.25. The City Engineer has evidenced his
approval by signing the final plat and the necessary easements shown on the plat.
5. Public utility easements eight (8) feet in width shall be shown on the plat for all existing
and proposed sewer stubs.
6. A minimum 8 -foot wide public utility easement must be provided adjacent to all public
road rights-of-way.
7. Easements for new and/or future utilities shall be a minimum of 16 feet in width, provided
that the width of easements for buried utilities will be twice the depth of the planned
excavation.
Status: Items 5 —7 above: Necessary easements are shown on the plat.
Plat of Whitecotton
Final Long Plat #1-04
Dale Whitecotton
Intersection of Mead Ave and Rock Ave
2
8. The final plat shall substantially conform to the preliminary plat, except as modified by the
hearing examiner or City Council.
Status: Achieved
9. All addresses shall be clearly shown on the face of the final plat.
Status: Achieved
10. The lots shall be subject to the following notes, which must be placed on the face of the
plat:
a. The addresses shown on this plat are accurate as of the date of recording, but may be
subject to change. The City of Yakima Building Codes Division is responsible for the
confirmation or reassignment of addresses at the time of building permit issuance.
Status: Achieved
CONCLUSION.
1. The final plat is consistent with the goals, objectives and intent of the Urban Area
Comprehensive Plan and the standards of the Urban Area Zoning Ordinance.
2. The final plat meets the standards of the City of Yakima Subdivision Ordinance.
3. The final plat is in general conformance with the preliminary plat and the relevant
conditions of approval.
4. All construction and required improvements necessary for final plat approval have been
financially secured or completed.
RECOMMENDATION
The City Engineer's office has inspected and accepted all required physical improvements and the
City Engineer has signed the plat in affirmation of this fact. The Planning Division has reviewed
the final plat and found it to be in substantial conformance with the terms and conditions of
preliminary plat approval. Staff, therefore, recommends City Council acceptance of the final plat
of Whitecotton and asks that the resolution authorizing the Mayor to sign the final plat be
adopted.
Plat of Whitecotton
Final Long Plat #1-04
Dale Whitecotton
Intersection of Mead Ave and Rock Ave
3
CITY OF YAKIMA, WASHINGTON
HEARING EXAMINER'S RECOMMENDATION
April 8, 2004
In the Matter of a Preliminary Plat
Application Submitted by:
Dale Whitecotton
For an Eleven -Lot Subdivision
At 48 West Mead Avenue, Yakima
Pre Plat #1-04
EC #2-04
Introduction. The Hearing Examiner conducted an open record public hearing on
March 25, 2004, and this recommendation has been provided within ten business days
thereof. The staff report presented by Assistant Planner Jeff Peters recommended
approval of this preliminary plat application with conditions. The applicant Dale
Whitecotton and his representative Jim Bell further described the proposal and requested
that one of the lots be allowed to continue to use an existing approach onto Mead
Avenue. City Engineering Division representative Kevin Callow explained safety issues
involved in that request. A letter was received by one person residing in the vicinity of
the proposed preliminary plat who opposed_additional housing in the area. Testimony by
and on behalf of residents of the existing mobile home park comprising the land here
proposed for eleven duplex lots was presented about the hardships imposed upon them by
having to move their mobile homes by the end of January, 2005. There are eight mobile
homes presently located on the property. The hardships faced by residents on fixed
incomes consist primarily of some moving expenses that may not be covered by the
State's mobile home relocation fund which is limited to $3,500 for a single wide and
$7,000 for a double wide mobile home; the lack of any guarantee that relocation funds
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
1
Filed
Hearing Examiner
EXH # Aft-( Date y 87- °Y
File# /-Ory
will be available; the possibility that the Department of Labor and Industries may impose
requirements to upgrade the homes if they are moved; the difficulty of locating another
mobile home park to move the older mobile homes to; the increase in rent that may result
from moving to a new location; the fact that some existing decks and other improvements
cannot be moved with the mobile homes; and the inconvenience and expense of moving
and storing the property within the mobile homes. The owner/applicant has given the
statutory one-year notice to the residents of the need to move within a year and has tried
to help them find the least expensive ways to move the homes and mobile home parks
that would accept the older homes.
Summary of Recommendation. The Hearing Examiner recommends approval of this
preliminary plat subject to the conditions set forth below.
Basis for Decision. Based on a view of the site on March 23, 2004 without anyone else
present; the staff report, application, exhibits, testimony and other evidence presented at
an open record public hearing on March 25, 2004; and a consideration of the applicable
comprehensive plan provisions, zoning requirements, consistency criteria, development
standards and subdivision requirements; the Hearing Examiner makes the following:
FINDINGS
Applicant/Property Owner. Dale Whitecotton, Box 9811, Yakima, Washington
98909.
Location. The proposed preliminary plat is located in the vicinity of 48 West Mead
Avenue, Yakima, Washington; Parcel No. 191331-21402.
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
2
DOC.
INDEX
Application. The application is to subdivide about 1.9 acres of land where eight mobile
homes are currently located into eleven two-family residential lots ranging in size from
7,000 to 9,000 square feet.
Notices. Public notice of this application and hearing was provided in accordance with
the notice requirements of ordinances relating to Title 14, Subdivision; Title 15, Zoning;
Title 6.88, Environmental Policy; and Title 16, Development Permit Regulations:
Notice of Application and Hearing: February 9, 2004
Property Posting: February 28, 2004
Legal Notice: March 3, 2004
Environmental Review. After reviewing the environmental checklist submitted with
the project, the SEPA Responsible Official determined that the proposal will not have any
probable significant adverse environmental effects and issued a Determination of
Nonsignificance on March 2, 2004. No SEPA appeal was filed within the 15 -day appeal
period.
Transportation Concurrency. A traffic Capacity Analysis completed on February
23, 2004 indicates that this development will not exceed the PM peak hour capacity of
the City's arterial street system and that reserve capacity exists on all streets impacted by
this development.
Zoning and Land Use of Site and Adjacent Properties. The site which is
currently a mobile home park is zoned Two -Family Residential (R-2). The adjacent
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
3
DOC.
INDEX
4 A- -/
properties are zoned and used as follows:
Direction Zoning Land Use
North B-2 Local Business
South R-2 Two -Family -Residential
West R-2 Two -Family -Residential
East R-2 Two -Family -Residential
Jurisdiction. The Hearing Examiner has jurisdiction to make a recommendation to the
Yakima City Council regarding this matter by virtue of Chapter 58.17 of the Revised
Code of Washington and Section 14.20.100 of the Yakima Municipal Code.
Comprehensive Plan. The Future Land Use Map and 1998 Comprehensive Plan
designate the subject property as suitable for Medium Density Residential development.
This Medium Density Residential designation is characterized by a mixture of single-
family detached residences and duplexes with a variety of other housingtypes at a
residential density ranging between 7 and 11 dwelling units per acre. The proposed
preliminary plat is consistent with Goal H3 which is to preserve and improve existing
residential neighborhoods; Objective G9 which is to encourage quality design while
achieving economic growth patterns; Objective L2 which is to establish a pattern of
development that supports a sense of community; and Objective H3.1 which is to
stabilize existing, viable neighborhoods.
Urban Area Zoning Ordinance. The proposed preliminary plat is consistent with the
Urban Area Zoning Ordinance which indicates in Subsection 15.03.030(3) that the Two -
Family Residential (R-2) zoning district is intended to establish and preserve residential
neighborhoods for detached single-family dwellings, duplexes and other uses compatible
with the intent of the district and also to locate moderate -density residential development
Plat of Whitecotton 4
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
DOC.
INDEX
# /
with densities up to twelve units per net residential acre in areas served by public water
and sewer that have police and fire protection. This preliminary plat is drawn so that all
lots will have access, be provided with all necessary public utilities, exceed the minimum
lot size for duplexes in the R-2 zone of 7,000 square feet and meet or exceed the
minimum lot width of 50 feet as measured at the rear of the required front setback as
specified by Table 5-2 in Chapter 15.05 of the zoning ordinance.
Comments Raised during Development Services Team (DST) Review and
During Testimony at Hearing. The comments at the DST meeting for this proposal
held on February 25, 2004 and the testimony at the public hearing included the following
topics:
i) Engineering Division -- Right of Way: This site fronts on Mead Avenue,
classified as a Minor Arterial requiring 80 feet of right-of-way, 40 feet on each side of the
centerline. The existing right-of-way created by plat of August 28,. 1899 is 30 feet. It is
not felt that a dedication of 10 feet of additional right-of-way is necessary in this location.
ii) Engineering Division -- Driveway onto Mead Avenue: There is an existing
sidewalk fronting this site. There exists a residential driveway approach from Lot 1 to
Mead Avenue. This driveway should be removed and replaced with matching curb.
iii) Engineering Division — Curb and Sidewalk on Rock Avenue: This site
also fronts on Rock Avenue, classified as a Local Access Street. The existing right-of-
way satisfies Title 12 standards. There is existing curb fronting this site. A 5 -foot -wide
sidewalk is required. The developer may remove the existing curb and replace it with
rolled curb to facilitate the sidewalk installation and driveways.
iv) Engineering Division — Utility Easement over Lot 11: There is an existing
utility easement along the southerly portion of Lot 11 which is the most southerly lot in
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
5
DOC.
INDEX
the proposed plat. Ordinance #1620 vacated an unused right-of-way in 1974 that added
25 feet of property onto the southern part of the property proposed for this plat. The
vacation ordinance language indicates that the entirety of the vacated street is to remain
subject to a utility easement and that no portion of the vacated street can be built upon
without first receiving permission from the City of Yakima. Without at least a portion of
this 25 -foot utility easement being available for building, any construction on proposed
Lot 11 of this proposed plat will be severely restricted. There is currently a sewer line
located within this vacated right-of-way that will require that no structures be built within
eight feet on either side of this sewer line. Apart from this restriction, however, the City
Engineer indicates that construction over the remaining portion of the vacated right-of-
way will not interfere with the operation or maintenance of this line. Since the vacation
ordinance creating the 25 -foot easement provides for a mechanism to permit building
over a portion of the vacated right-of-way, a note may be added to the face of this final
plat indicating that buildings may be placed over the vacated right-of-way portion of Lot
11 provided no structures are placed within eight feet on either side of the centerline of
the existing sewer line.
v) Engineering Division — Sewer Lines: There is an existing sewer line in Rock
Avenue fronting this site and also along the rear or east property line of this proposal.
The owner has the option to utilize either line for sewer service to the preliminary plat.
Connection to the line along the rear or east property line is preferred because too many
cuts in the asphalt on Rock Avenue may necessitate an overlay at the applicant's expense.
Sewer stubs are in place to serve some of the lots. Additional stubs will need to be
installed. The sewer stubs providing service to each lot is a plat requirement to satisfy
Title 12 development standards. It is the owner's responsibility to ensure that stubs are
extended to the property line of each parcel. An 8 -foot -wide public utility easement is
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
6
DOC.
INDEX
required where all existing sewer stubs and proposed sewer stubs are located. A civil
site plan is required to show the location of all easements and improvements, including
the design and location of the driveways.
vi) Engineering Division — Corner Radius: The property corner where Rock
Avenue intersects with Mead Avenue should be rounded to a radius of 20 feet and the
property necessary to do so should be dedicated with this plat.
vii) Traffic Division — Driveways and Sidewalk: No site plan was submitted for
review to determine the location or width of driveways. Each of the eleven lots may
result in a duplex. On -street parking will likely be limited if each lot has an individual
driveway onto the public street. Construction of a sidewalk along the frontage of Rock
Avenue is noted in the application. Traffic Engineering supports the development of a
sidewalk with this new project.
viii) Water/Irrigation Division — Meters and Lines: LID connection charges to
the water main along Rock Avenue may apply to this development dependent upon meter
size. The City may install one or two services per lot. The applicant will have credit for
one 1 -Y2 -inch meter and separate meters are suggested, one for each unit. Broad gauge
irrigation owned by the New Schanno ditch company is within the area. These irrigation
lines are required to be shown on the face of the plat.
ix) Building Code Addressing: Unless other numbers are later assigned,
addresses for the lots will be: Lot 1: 48 West Mead Avenue; Lot 2: 1505 Rock Avenue;
Lot 3: 1509 Rock Avenue; Lot 4: 1511 Rock Avenue; Lot 5: 1513 Rock Avenue; Lot
6: 1515 Rock Avenue; Lot 7: 1517 Rock Avenue; Lot 8: 1519 Rock Avenue; Lot 9:
1521 Rock Avenue; Lot 10: 1523 Rock Avenue and Lot 11: 1525 Rock Avenue.
Consistency Analysis under Section 16.06.020(B) of the Yakima Municipal
Code. The following conclusions concern the application's consistency with applicable
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre P1at#1-04; EC#2-04
7
DOC.
INDEX
# A A' (
development regulations, or in the absence of applicable regulations, the adopted
Comprehensive Plan. During project review, the City of Yakima or any subsequent
reviewing body must not re-examine alternatives to, or hear appeals on, the items
identified in these conclusions except for issues of code interpretation.
a) The type of land use contemplated by the proposal (a residential
development) is permitted on the property included in the proposed plat, subject to
conformance with the regulations of the zoning ordinance, subdivision ordinance and
building codes.
b) The level of development (lot size, contemplated density) will not exceed the
allowable limits.
c) The availability and adequacy of infrastructure and public facilities
identified in the comprehensive plan are not an issue. Access will be by way of Rock
Avenue only. Even though the applicant has urged that the existing driveway onto Mead
Avenue be allowed to continue, Kevin Callow of the Engineering Division detailed
legitimate safety concerns involved. Mead Avenueis four lanes with no center tum lane
in this location and the existing driveway is near the intersection with Rock Avenue.
Since the owner/applicant was allowed to utilize either type of curb desired, either sewer
line desired, and all but 16 feet of the width of the utility easement over Lot 11, the City's
position regarding elimination of the existing driveway is not unreasonable. Water and
sewer services and other utility services such as electrical service, telephone service and
garbage service are available for this proposed preliminary plat.
d) The character of the proposal, such as the proposal's consistency with
applicable development standards of the City of Yakima Urban Area Zoning
Ordinance, allows for approval of the proposed preliminary plat. Although the effect of
this development upon the existing residents is regrettable and worthy of empathy, the
law regarding mobile home parks allows them to be discontinued if specified procedures
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
8
DOC.
INDEX
# A-4-1
are followed. Residents must be given a year's notice to move. Residents may each be
eligible for $3,500 or $7,000 of State relocation funds toward the cost of moving their
homes. The law does not provide complete relief for all the hardships residents face
when mobile home parks are discontinued. But the law does allow them to be
discontinued. The owner here could discontinue the mobile home park use of his
property regardless of whether this preliminary plat is approved. That is a separate right
that is not a consideration in the plat process except insofar that the applicant here
appears to be genuinely concerned and willing to help the residents find movers and
places to move. There were indications at the hearing of an interest on the part of some
to procure resources to purchase the property so that the park could remain, which may
be a practical option if the resources are available. In any event, the proposed
preliminary plat complies with the R-2 minimum lot size requirements and other
applicable development standards.
CONCLUSIONS
1. The Hearing Examiner has jurisdiction to make a recommendation to the Yakima
City Council regarding this application for preliminary plat approval.
2. Public notice has been provided in accordance with applicable ordinance
provisions.
3. The SEPA Determination of Nonsignificance has become final for lack of any
appeals during the applicable appeal period.
4. The proposal satisfies traffic concurrency requirements.
5. The residents of the mobile home park on the property expressed concerns at the
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre P1at#1-04; EC#2-04
9
DOC.
INDEX
# A -A-- f
public hearing which may be ameliorated to some extent by financial relocation
assistance laws and by the one-year notice required by mobile home landlord/tenant laws,
but those concerns, however legitimate, do not prevent an owner from legally
discontinuing a mobile home park by compliance with applicable procedures or prevent
an owner from obtaining preliminary plat approval for the property.
6. After inquiring into the public use and interest proposed to be served by the
establishment of the subdivision and dedication, the Hearing Examiner recommends
approval of the preliminary plat with the conditions detailed below which make
appropriate provisions for the public health, safety and general welfare and for open
spaces, drainage ways, streets or roads, alleys, public ways, transit stops, potable water
supplies, irrigation and other water supplies, sanitary waste disposal, parks and
recreation, playgrounds, schools and schoolgrounds, sidewalks and other planning
features that assure safe walking conditions for students who only walk to and from
school, and which conditions also ensure that the public use and interest will be served by
the approval of this subdivision as required by Section 14.20.100 of the Yakima
Municipal Code.
7. This application for preliminary plat approval can be adequately conditioned by
the conditions set forth below so as to ensure compatibility, compliance and consistency
with the provisions of the zoning district and with the goals, objectives and policies of the
comprehensive plan and to satisfy all applicable requirements of City and State plat laws.
RECOMMENDATION
The Hearing Examiner recommends to the Yakima City Council that the eleven -lot
preliminary plat described in the application and in the documents which are assigned the
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
10
DOC,
INDEX
# A „
file numbers Pre Plat #1-04 and EC #2-04 be APPROVED, subject to the following
conditions:
1. The residential driveway approach from Lot 1 onto Mead Avenue shall be
removed and replaced with matching curb.
2. A sidewalk five (5) feet in width shall to be installed along Rock Avenue, with
either a rolled or barrier curb at the owner's option.
3. Additional sewer stubs shall be installed to connect either with the sewer line
along Rock Avenue or with the sewer line along the rear (east) property line at the
owner's option, one sewer stub for each structure that shall be extended to the
property line of each parcel.
4. Public utility easements eight (8) feet in width shall be shown on the plat for all
existing and proposed sewer stubs.
5. The property corner where Rock Avenue intersects with Mead Avenue shall be
rounded to a radius of twenty (20) feet and the property necessary to accomplish
that result shall be dedicated with this plat.
6. A note shall be placed conspicuously on the face of the final plat stating:
"Buildings may be placed over the vacated right-of-way portion of Lot 11
provided that no structures are placed within eight (8) feet on either side of the
centerline of the existing sewer line."
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
11
DOC.
INDEX
7. All irrigation lines and easements shall be shown on the face of the plat.
DATED this 8t day April, 2004.
Plat of Whitecotton
48 West Mead Ave.
Parcel #191331-21402
Pre Plat#1-04; EC#2-04
12
Gary M. Cuillier, Hearing Examiner
DGS``.
INDEX
—
Q
z
z
m
W KING ST
L
W PIERCE ST
1111
MEAD AVE
LANDON AVE
IV P169. BT
0
LEDWICH AVE
W Kinn St
CITY OF YAKIMA, WASHINGTON
VICINITY MAP
PILE NO: PREL LONG PLAT#1-04 & UAZO EC#2-04
APPLICANT: DALE WHITECOTTON
REQUEST: 11 LOT SUBDIVISION IN THE R-2 ZONE
WITH ENVIRONMENTAL REVIEW
LOCATION: VICINITY OF 48 W. MEAD AVENUE
Subject
Yakima
Scale —lin = 400ft
Property
City Limits
0 200 4IGPLT--1-0401/30/04
PLAT GORI.10R
GSD M014 AFµ 124.298
G 0
`NATER MAkJ
Preliminary Plan
PLAT OF WHITECOTTON
IN THE NE' A, NW 'A, SECTION 31-13-19
PARCEL NUMBER 191331-21402
M E A D A V E N U E
1.1 00' 00' E ( REF PRCr'1
133-1 28
Li]
N
d
3
73
w
186 10
8' WATa=9Z MAIN
9 1 T 0
SLOT 1
7000 SQ FT
SLOT
7000 SQ FT
SLOT 3
4' 7750 SQ FT
O
O
S
3 s
0
O y
N 0
0
Y 8' cel
i N
1490' 00'E
50.00
Q
0
NS
LOT 4
736'0 SQ FT
ALLI MIU LAM CAP
16909 AT-
P tER.C.E.
TPIERCE hTREET
m
i
06
et
s
25�
8'
LOT 5
7360 SO FT
LOT 6
7360 SQ FT
LOT 7
7360 SQ FT
LOT 8
7360 SO FT
LOT 9
7360 SO FT
l'J
a
a1 ro
w1 '
111 I co)
4, la,
to -
" 99
SUE IVtSION
LOT 10
7360 SO FT
I 4.
8
1 1-
LO
S N
LOT 11
9140 SO FT
I
Io
I
EXI8T1NCr 25 UTILITY I I
EFASEMELIT OR0.1.10. 1620 I
14158 !
555w
55-(_155 -'
30" 9gµ1TARY Sev✓E2
40
499.74
55
N 89' 05 20"r u/ 666 32
�- EXISTIN(r 8' LLTILTY ESMT
PLAT OF RoCI AVENUE
ROCK AVENUE ADD VOL'Z" PG 10
Rock AVENUE 15 30' ASPHALT wlTu
BARRIER GURO
M EAC, AVe tUE Ih 4E; AS Pt-L4LY vJITht
BARRIER. CLIRe, AlJD S' S1G0VJALK
0
0
2
J
670.48
NORTH '�4 CORI45R
56G -(10N 81- 13 - 1'3
GSD. MON 2M-1568
1" = Ioo`
MAR 0 bi 217n4..
BUSINESS OF THE CITY COUNCIL
YAKIMA, WASHINGTON
AGENDA STATEMENT
Item No. 7
For Meeting of November 2, 2004
ITEM TITLE: Public Meeting to consider the final plat of Whitecotton submitted by Dale
Whitecotton.
SUBMITTED BY: William R. Cook, Director of Community & Economic Development
CONTACT PERSON/TELEPHONE: Jeff Peters, Assistant Planner, 575-6163
SUMMARY EXPLANATION:
Whitecotton is an 11 -lot subdivision located at the intersection of Mead Ave. and Rock Ave. In
open Council session on May 18, 2004 the Hearing Examiner's recommendation to approve this
preliminary plat was accepted and preliminary plat approval was granted subject to conditions.
The City Engineer's office has inspected the plat and accepted the required securities for this
plat. The City Engineer has also signed the plat in affirmation of this fact. The Planning Division
has likewise reviewed the final plat and finds it also to be in substantial conformance with the
terms and conditions of the preliminary plat decision.
YMC 14.20.210 sets forth the following process for final plat approval:
A. Upon receipt of a proposed final plat, the City Council shall at its next public meeting set a
date for consideration of the final plat. Notice of the date, time, and location of the public
meeting shall be given to the subdivision applicant, Surveyor, City Engineer, Office of
Environmental Planning, and the Yakima County Health Officer at least four days prior to the
date of the public meeting.
B. The City Council shall review the final plat during the public meeting and shall approve the
final plat if the Council determines that the final plat conforms to the conditions of preliminary
plat approval and applicable state laws and meets the requirements of this title as they existed
when the preliminary plat was approved.
C. Upon approving any final plat, the City Council shall authorize the Mayor to sign the final plat
as evidence of City Council approval. (Ord. 98-65 § 2 (part), 1998).
Resolution X Ordinance_ Contract Other (Specify) Staff Report, Hearing
Examiners Decision, Final Plat Diagram
Funding Source
APPROVAL FOR SUBMITTAL: -
City Manager
STAFF RECOMMENDATION: Adopt resolution authorizing the Mayor to sign the final plat of Whitecotton.
BOARD RECOMMENDATION: The Hearing Examiner recommended preliminary plat approval on April
8, 2004
COUNCIL ACTION: Final Plat approved. RESOLUTION NO. R-2004-168