Loading...
HomeMy WebLinkAbout1960-184 ORDINANCE VO. 0 AN ORDINANCE amending Sections 27, 85, and 102 of Ordinance No B-2137, entitled, "AN ORDINANCE relating to and regu- lating plumbing; including provisions relating to the water supply and drainage in plumbing systems; creating an examining board for plumbers; defining eertvin terms; establishing regulations for the installation, alt e a- tion, or repair of plumbing and drainage system; and the inspection thereof; requiring licenses and, permite; pre- scribing fees; providing pen=lties for its violation; • and repealing co flicting ordinances," and declaring =n emergency, BE IT ORDAINED BY THE CITY OF YAKIMA: Section 1. That Section 27 of Ordinance Na, Be2137 shall be amended by adding thereto a new sub-section (c) which shall read as follows: "Sction 27. SPECIAL REQUIREMENTS FOR MATERIALS, (c) Copper tube for underground drainage and vent piping shall have a weight of not lees than that of Copper Water Tube, Type L, A.S.T.M. B-88-58, 0 Copper tube for above ground drainage and vent piping shall have a weight of not less than that of Copper Drainage Tube Type DWV A.S.T.M. B-306-58." Section 2 That Section 85 of Ordinance No B-2I-37 is hereby amended to read as follows, to-wit: "Section 85. SIZES OF SOIL AND WASTE PIPE. The maximum number of fixture units that may be connected to a given size of hori zontal branch, building drain, vertical soil or waste stack or building sewer is set forth below. In no case shall the waete pipe be smaller than the trap it serves. No horizontal waete pipe of 116 inches shall exceed 25 feet in length, Maximum fix- ture units that may be connected to building drain, moil or waste pipes are as follows: Pipe size inches Fixture units 2 13 4 2. 8 216 21 3 48 • 4 198 • 576 6 1000 • 8 2300 10 4200 • 12 6700 15 • 120000 -1- Water closets shall not be connected to soil pipes less than -410 four (4) inches in diameter. Water closets may be connected to copper tube soil pipes of three (3) inches in diameter. When provision is made for the future installation of fixtures, those provided for shall be considered in determining the re- quired size of drain pipes. Construction to provide for such future installation shall be terminated with a plugged fitting„ or fittings, at the stack, so as to form no dead end, and shall be provided with a vent opening." Seetion3 That Section 102 of Ordinance No B-21-37 is hereby amended to read as follows, to-wit: "Section 102. SIZE AND LENGTH OF VENTS. Size of all vents extending through the roof must be at least equal in cross- sectional area of the main house drain to which they connect. All main lines of soil and waste pipes shall be extended full size through the roof. The main vent pipe in buildings where water closets or eight unit drains are installed shall be at least four inches in diameter, except where copper tube is used, in which case the pipe shall not be less than 3 inches in diameter, and in either case shall be extended full size through the roof. All vents shall be at least one and one fourth inches in diameter, 1 10 In determining the developed length of vent pipes, the vent stack and branches shall be considered continuous from the longest vent connection; provided, that the minimum size of individual vents shall not be less than: For Unit Trap Pipe Size 1 134 inches 2 ih inches 4 2 inches 5 2 inches 6 2 inches 8 2 inches 12 3 inches 22 3 inches 44 4 inches 64 4 inches The required size and length of vents shall be determined in accordance with the following table: FIXTURE UNITS CONNECTED 1 lh 2 2h 3 45 6 8 10 12 • 1 50 100 200 2 40 80 160 3 60 120 240 4 50 100 200 6 40 80 160 -2- FIXTURE UNITS CONNECTED (Cont,) .411 1% 136 2 216 3 4 5 6 . 8 10 12 7-12 60 120 240 13-18 50 100 200 19-24 40 80 160 25-40 75 150 300 41-56 . 60 120 240 57-72 50 100 200 73-92 100 200 400 93-114 80 160 320 115-136 60 120 240 137-250 250 500 1000 251-366 200 400 800 367-480 150 300 600 481-686 300 600 1200 687-892 250 500 1000 ' • 893-1100 . 200 400 800 1101-1366 400 800 13671632 300 600 1633-1900 250 500 1901-3600 UnliMited 3601-5600 Unlimited 5601-7400 Unlimited 7401-18000 , Vn1imited7 • Section 4. This ordinance is one to provide for the immediate preservation of the public peace, property, health and safety of the people of the City of Yakima n and an emergency is hereby declared to exist and this ordinance shall be in full force and effect immediately upon its passage n approval and publication as provided by law and the City Charter. PASSED BY THE CITY COUNCIL 0 signed and approved this 2nd day of November, 1960. 5 i)i;O.6ein ATTEST: - ' .4. 11.--------- -3-